A40 battery cabinet with breaker box indoor Electric Control Cabinet with OEM custom
Brief introductions:
A series battery cabinet is designed to enhance safety & thermal efficiency of batteries; also it achieves easy maintenance of batteries and beautifies the whole power system. It meets the access & maintenance standards of standby battery in accordance with IEC.
Additionally, A series battery cabinet assists decreasing unnecessary power drain, interference or degeneration of batteries as well.
Key features:
1. Light steel stuff , firm & flexible
2. Components design makes transferring & removing easy, fast and safe l Wheels optional
3. Ring type terminal battery wires available
4. Circuit breaker for over current protection optional
5. Built-in radiator l Insulated wire output
battery box/ battery cabinet battery cabinet
NO | Size (mm) | KG | Battery Type | ||||||
A-1S | 400*200*260 | 3 | AH | 17AH | 24AH | 38AH | 65AH | 100AH | 120AH |
QTY | 3 | 2 | 1 | 1 | / | / | |||
A-1B | 570*230*280 | 7 | AH | 17AH | 24AH | 38AH | 65AH | 100AH | 120AH |
QTY | 5 | 4 | 3 | / | / | / | |||
A-1 | 470*220*310 | 4 | AH | 17AH | 24AH | 38AH | 65AH | 100AH | 120AH |
QTY | 4 | 3 | 2 | 1 | 1 | 1 | |||
A-2 | 450*450*350 | 6 | AH | 17AH | 24AH | 38AH | 65AH | 100AH | 120AH |
QTY | 8 | 6 | 4 | 2 | 2 | 2 | |||
A-3 | 600*450*350 | 9 | AH | 17AH | 24AH | 38AH | 65AH | 100AH | 120AH |
QTY | 12 | 9 | 6 | 3 | 3 | 3 | |||
A-4 | 500*415*618 | 16 | AH | 17AH | 24AH | 38AH | 65AH | 100AH | 120AH |
QTY | 16 | 12 | 8 | 4 | 4 | 4 | |||
A-6 | 620*470*618 | 19 | AH | 17AH | 24AH | 38AH | 65AH | 100AH | 120AH |
QTY | 24 | 18 | 12 | 6 | 6 | 6 | |||
A-8 | 780*470*618 | 21 | AH | 17AH | 24AH | 38AH | 65AH | 100AH | 120AH |
QTY | 32 | 24 | 16 | 8 | 8 | 8 | |||
A-10 | 960*470*618 | 26 | AH | 17AH | 24AH | 38AH | 65AH | 100AH | 120AH |
QTY | 40 | 30 | 20 | 10 | 10 | 10 | |||
A-12 | 780*470*928 | 30 | AH | 17AH | 24AH | 38AH | 65AH | 100AH | 120AH |
QTY | / | 24 | 24 | 12 | 12 | 12 | |||
A16 | 780*470*1230 | 40 | AH | 17AH | 24AH | 38AH | 65AH | 100AH | 120AH |
QTY | / | 32 | 32 | 16 | 16 | 16 | |||
A20 | 960*470*1230 | 46 | AH | 17AH | 24AH | 38AH | 65AH | 100AH | 120AH |
QTY | / | / | 40 | 20 | 20 | 20 | |||
A-32 | 780*880*1228 | 75 | AH | 17AH | 24AH | 38AH | 65AH | 100AH | 120AH |
QTY | / | / | / | 32 | 32 | 32 | |||
A-40 | 780*880*1528 | 95 | AH | 17AH | 24AH | 38AH | 65AH | 100AH | 120AH |
QTY | / | / | / | 40 | 40 | 40 |
FAQ
Will need to install the battery in accordance with the requirements for correct polarity emissions in place, messenger wire way neatly adjust to ensure that all cells in a horizontal direction. Then connect copper platoon or connect the cable to the top of the two adjacent terminals is put one by one, insert the connecting bolts, wear the nut by hand (copper platoon connection).Inspect all bore copper platoon and terminal location whether appropriate, necessary exchange copper platoon or mend the hole on the copper platoon position, ensure that after the bolt fastening may not produce stress for the column. Then use the torque wrench bolts to the required torque value one by one.
In the connection operation, be sure to use with the insulation protection of tools; Don't put the instrument or any metal objects on the top of the battery, in case of short circuit damage battery. Pay attention to keep 1 cm between each battery monomer space for heat dissipation, also is each section battery around 1 cm gap, heat dissipation, otherwise it's easy to have a hot while charging out of control and lead to battery fire.