Low frequency UPS from 10kva to 40kva:
Model | GP3110K | GP3115K | GP3120K | GP3130K | GP3140K | |
Capacity | 10KVA/8KW | 15KVA/12KW | 20KVA/16KW | 30KVA/24KW | 40KVA/32KW | |
INPUT | ||||||
Norminal Voltage | 3*380VAC (3PH+G or 3PH +N+G) | |||||
Acceptable voltage range | 304VAC~456VAC | |||||
Frequency Range | 50Hz±5Hz(±10%) | |||||
OUTPUT | ||||||
Norminal voltage | 220VAC/230VAC/240VAC(Selectable) | |||||
Connection type | Hardwire 3-wire (1PH+N+G) | |||||
Waveform | Pure Sine wave | |||||
Output voltage stability | steady state | ±1% | ||||
Transient state | ±5% | |||||
Frequency | 50Hz | |||||
Frequency Synchronization range | ±1% | |||||
Frequency Synchronization speed | 1·2Hz/s | |||||
Power factor | 0.8 | |||||
Crest Factor | 3:01 | |||||
Total Harmonic Distortion(THDv) | ≤2% (linear load); ≤4% (non-linear load) | |||||
Dynamic in-rush voltage range | 0%->100%->0%(R load)<±5%; 20%->100%->20%(Rload)±3%; | |||||
Dynamic Recovery Time(III Grade) | 0~100% RCD load;<60ms recover to 90% of norminal voltage | |||||
Phase Displacement | 120°±1%(balanced load); 120°±2%(imbalances 50% of the load) |
Transfer time | 0ms | |||||
Overload Capacity | 0~110% continuous running; 110%~150% for10min~1min;>160% for 200ms | |||||
Short-circuit capacity | 60~100ms | |||||
Transient response time | <5ms | |||||
BYPASS | ||||||
Connection Type | Hardwire 3-wire(1PH+N+G) | |||||
Input Voltage range | 220VAC±25% | |||||
Overload Capacity | 1.5In~1.8In 1h-30s | |||||
Short-circuit capacity | 1.8In~2.0In 30s~200ms | |||||
SYSTEM | ||||||
Efficiency(At linear load and 270VDC) | 85% | 86% | 86% | 88% | 89% | |
ECO mode(Non-parallel models) | Yes | |||||
EPO Function | Yes | |||||
Standard | IEC 61000-4-5 Protection surge;IEC62040-1 EMC/EMI, IEC62040-1 Safety | |||||
BATTERY | ||||||
Battery | Type | Support VRLA Battery | ||||
Number | 16-18pcs | |||||
Reverse Diode | Yes | |||||
Cold start | Yes | |||||
PHYSICAL | ||||||
IP Protection | IP20(Default),IP21/31(oPTIONAL) | |||||
Dimension,D×W×H (mm) | 570×450×900 | 700×450×1050 | ||||
Net Weight(KGS) | 125 | 135 | 200 | 280 | 310 | |
ENVIRONMENT | ||||||
Operating Temperature | 0~35℃ continuous running.40℃ 8hs running at nominal input voltage, recharging batteries and no overload, 45℃ derating to 85% with linear load | |||||
Humidity | 0~90% (Non-Condensing) | |||||
Noise level | less than 70dB @ 1 Meter | |||||
MAINTENANCE | ||||||
Modbus RS-232/RS485 | Support Windows 2000/2003/XP/Vista/2008/7/8,Linux and MAC | |||||
Dry contacts | 6 outputs and 2 inputs | |||||
Optional SNMP | Power management from SNMP manager and Web browser |